8 M I N I L I N E C LV 5 0 3 / C LV 5 0 5 / I C R 8 0 3 | S I C K 2 0 0 9 - 09
Technical
data
C LV 5 0 3 C LV 5 0 5 I C R 8 0 3 - A / - B
Scanner design 1D Code Reader 2D Image Code Reader
Light source
LED illumination – Visible red light (630 nm)
LED aiming line – Visible green light (530 nm)
Laser diode (wavelength) Visible red light (650 nm) –
Laser class of device
1)
Class 2 –
MTTF
2)
of laser diode 10,000 h –
Immunity to ambient light 2,000 lx Max. 100,000 lx
Resolution 0.15 mm to 1.0 mm ICR803-A:
0.19 mm (1D); 0.21
mm (2D)
ICR803-B:
0.33 mm (1D); 0.38 mm (2D)
Usable aperture Max. 44° Max. 40° –
Scanning /decoder frequency 100 Hz 1,000 Hz –
Bar
codeprintcontrast(PCS) 90 %; min. 45 % –
Acoustic indicators
3)
Beeper(buzzer) Beeper
Clock reading pulse Digital input/command Manual trigger, command or
Presentation Mode, hardware
triggerviaCDB405
Data interfaces USB
keyboardwedge,USBserial,RS232 USBkeyboardwedge,USBserial,
RS 232 TTL
Digital switching inputs 1 x input for clock reading pulse –
Digital switching outputs 1 x GoodRead, 1 x NoRead –
Electrical connection 1.5
mcablewithUSBoropenwireends RJ45 socket: separate RJ45 cable
toUSBor9-pinDSubforRS232
Operating voltage 5 V DC ± 10 %
Power consumption Typ. 85 mA, max. 150 mA Typ. 205 mA, max. 500 mA Typ. 350 mA
Weight 18.5 g without cable 30 g without cable 37 g without cable
Dimensions 30 mm x 43.3 mm x 20 mm 29 mm x 34.5 mm x 17 mm 49 mm x 40 mm x 25 mm
Enclosure rating IP 43 IP 54 –
Laser protection JIS-C-6802 class 2, IEC 60825-1 class 2, FDA CDRH class II –
EMC testing Emission of interference acc. to
EN 61000-6-3:2007-01;
immunity to interference acc. to
EN
61000-6-1:2007-01
4)
Emission of interference acc. to
EN 61000-6-3:2007-01;
immunity to interference acc. to
EN 61000-6-2:2007-01
5)
Emission of interference acc.
to EN 55022:1998/A1:2000/
A2:2003 Class A ITE;
immunity to interference acc. to
EN 55024: 1998/A1:2001/
A2:2003 ITE
Product complies with CE, FCC
6)
, VCCI, RoHs CE, FCC
6)
, RoHs
Operating temperature –10 to 45 °C 0 to 45 °C 0 to 50 °C
Relative air humidity 20 to 85
%, non-condensing 5 to 90 %, non-condensing 5 to 95 %, non-condensing
1)
According to IEC 60825-1 and EN 60825-1, see warning sign on device for publication date;
2)
MTTF = Mean Time To Failure;
3)
Can be deactivated;
4)
CLV503-0110:ProtectionfromESDisrequiredbyeithergroundedorESDsafemounting.TheUSBcablelengthshallnotexceed3m;CLV503-0000:Device
must either be mounted on an isolated support or be protected from ESD;
5)
Safe mounting with ESD;
6)
FCC = Federal Communications Commission