- 19 -
Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 bar codes, but you want the imager to
output Code 39 1st, Code 128 2nd, and Code 93 3rd, as shown below.
Note: Code 93 must be enabled to use this example.
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLK sequence editor start command, 62 code identifier for Code 39, 9999 code length that must match
for Code 39 (9999 = all lengths), 41 start character match for Code 39 (41h = “A” ), FF termination string for
first code, 6A code identifier for Code 128, 9999 code length that must match for Code 128 (9999 = all
lengths), 42 start character match for Code 128 (42h = “B”), FF termination string for second code, 69 code
identifier for Code 93, 9999 code length that must match for Code 93 (9999 = all lengths), 43 start character
match for Code 93 (43h = “C”), FF termination string for third code
Commenti su questo manuale