- 14 -
Imager Time Out
Imager Time Out powers down the imager after the unit has been idle for the specified time. To
prevent the imager from powering down, set this time out to 0. Scan the bar code below, then set
the time out by scanning digits (from 0 - 999,999 ms) from Appendix D, then scanning Save.
Aimer Delay
The aimer delay allows a delay time for the operator to aim the imager before the picture is taken.
Use these codes to set the time between when the trigger is pulled and when the picture is taken.
During the delay time, the aiming light will appear, but the LEDs won’t turn on until the delay time is
over.
Aimer Mode
This feature allows you to lower peak current during scanning by alternating the aimer and
illumination LEDs. When the Interlaced bar code is scanned, the aimer and illumination LEDs are
not allowed to be on at the same time. While this does limit peak current during scanning, the
scanner performance may be slower. When the Concurrent bar code is scanned, the aimer and
illumination LEDs are allowed to light at the same time. Select Off if you don’t want to use either
aimer mode.