10.10.4 Important clarifications
Sketch out the reading situation and enter the parameter values and variables for the CLV.
Determine the reading range and installation height of the CLV above the conveyor belt:
With a covered conveyor belt with a 600 mm width, the CLV can read an object at a di-
stance of 600 mm (according to the reading field diagram in
Fig. 10-1, Page 10-3
). For
a reserve of an additional 100 mm and a maximum package height of 600 mm, the re-
sulting reading range of the CLV can be set to 700 ... 1 300 mm from the reading window.
The CLV is to be mounted 1 400 mm above the conveyor belt, as the package must be
at least 100 mm high.
Determine the CLV’s distance measurement type:
For the required total field depth range of 600 mm, a height detection of the focal po-
sition changeover is required. This is carried out by activating the CLV’s direct distance
measurement (the basis of the autofocus function).
10.10.5 Mounting and electrical connection
1. Mount the CLV centered 1 400 mm above the conveyor belt (vertically) according to
a)
Fig. 10-44
, reading window facing downward.
2. Align and screw in the CLV in a reading axis with the reading window at a 10
°
angle
against the required reading direction as shown in b)
Fig. 10-44
The CLV can carry out a distance measurement from the front of the package to the
top of the package while it is in motion.
3. Attach the pulse photoelectric switch and reflector to the conveyor belt so that there is
a distance of approx. 100 mm between the photoelectric switch and the scan line
position on the package with the smallest height.
4. Connect the CLV to the AMV/S 60 connection module.
(
see Chapter 5.2.3 Connections/cables for the AMV/S Connection Module, Page 5-3
)
5. Connect the pulse photoelectric switch to the AMV/S 60 connection module
(see
Chapter 5.5.7 Connecting the switching inputs, Page 5-16
).
6. Turn on the supply voltage to the CLV.
Fig. 10-44: Parameterization example: prepare a sketch of the reading situation
Y1Y2
Z1
10
Z2
550
200
300
700
100
1400
600
LS
100
All values in mm
alpha = 270
°
beta = 10
°
b) Side view
a) View from the front
z coord.
y coord.
x coord.