Chapter 10 Operating Instructions
CLV 490 Bar Code Scanner
10-56
©
SICK AG · Division Auto Ident · Germany · All rights reserved 8 008 796/0000/25-06-2002
Appendix
10.10 Discussion of a parameterization example
10.10.1 Application Conditions
Reading with the CLV 490’s autofocus function
Reading the packages from above
Barcode with lines running vertically on the top side of the package, tilt across from the
scan line:
±
30
°
Package height: 100 ... 600 mm, package width: 200 ... 550 mm, packages not guided
Conveyer velocity: v = 1 m/s, conveyer belt width: 600 mm
Object distance between packages: min. 300 mm
Barcode: 2/5 Interleaved, module width 0.4 mm, line length 15 mm, PR 2.5:1,
Quality 3 or 4, 14 characters with test code (mod 10)
Do not read under plastic sheeting, do not use very dark packages
(spectral reflection > 20 %)
1 barcode per package
Reading pulse is through a SICK photoelectric switch
Output of read results via the host interface
Parameterization of the CLV based on the factory defaults
Requirements:
Testing the application for feasability with the CLV 490 before buying, with the help of
the SMART calculation sheet (service provided by SICK)
Choice of CLV type: here standard density line scanner (CLV 490-0010)
No objects irrelevant for reading portruding into conveyor path
Tools:
Measuring tape (up to 3 000 mm)
Protractor (to set up the CLV)
A PC with Windows and the SICK software "CLV-Setup"
RS-232 interface (pin 2 and pin 3 crossed), e. g. no. 2 014 054
These operating instructions
10.10.2 Purpose of this discussion
To make important clarifications
To indicate the fitting location of the CLV
To point out the parameters to be set in the CLV-Setup user interface
10.10.3 Instructions for solution – step by step
Determine the reading range and CLV’s installation height over the conveyor belt
Determine the CLV’s distance measurement type
Mount the CLV
Parameterize the CLV
Test an application